User’s Manual Pub. 0300257-01 Rev. A
Point IO™
2/4 Channel Analog HART Module
Catalog Number: 1734sc-IE2CH / IE4CH
Vue de la page 0
1 2 3 4 5 6 ... 83 84

Résumé du contenu

Page 1 - Point IO™

User’s Manual Pub. 0300257-01 Rev. A Point IO™ 2/4 Channel Analog HART Module Catalog Number: 1734sc-IE2CH / IE4CH

Page 2 - Important Notes

1-2 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Section 1.5 Hardware Features Channels are wired as differenti

Page 3 - Table of Contents

Chapter 1: Module Overview 1-3 User’s Manual Pub. 0300257-01 Rev. A 1.5.1 LED Indicators The 1734 analog HART module uses several LEDs to show oper

Page 4

1-4 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A functions. If no faults are found during power-up diagnostics,

Page 5

User’s Manual Pub. 0300257-01 Rev. A Chapter 2 Installation and Wiring This chapter will cover: • Compliance to European union directives • Power

Page 6

2-2 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A 5 VDC 24 VDC 15 mA 20 mA Use the table below to determine the

Page 7 - Used in This

Chapter 2: Installation and Wiring 2-3 User’s Manual Pub. 0300257-01 Rev. A 2.3.2 Prevent Electrostatic Discharge !Attention Electrostatic dischar

Page 8

2-4 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A wiring base assembly is one of the following: • 1734-TB or 1734

Page 9 - Module Overview

Chapter 2: Installation and Wiring 2-5 User’s Manual Pub. 0300257-01 Rev. A 2.4.2 Install Mounting Base !Attention During panel or DIN rail mount

Page 10 - Features

2-6 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A 1.) Using a bladed screwdriver, rotate the key switch on the m

Page 11 - 1.6.1 Module Power-up

Chapter 2: Installation and Wiring 2-7 User’s Manual Pub. 0300257-01 Rev. A vertical position. This releases the locking mechanism. 7.) Lift strai

Page 12 - 1.6.2 Module Operation

ii Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Important Notes 1. Please read all the information in this owner

Page 13 - Installation and Wiring

2-8 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Grounding !Attention USE SUPPLY WIRES SUITALE FOR 10°C ABOVE SU

Page 14 - Considerations

Chapter 2: Installation and Wiring 2-9 User’s Manual Pub. 0300257-01 Rev. A Table 2-2 (2 Ch Terminal Block Pinout) RTB Pin# Usage Usage RTB Pin#

Page 15 - Attention

2-10 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A

Page 16

User’s Manual Pub. 0300257-01 Rev. A Chapter 3 Configuring the 1734sc-IExCH Using RSLogix 5000 This chapter covers the following subjects: • Intro

Page 17 - 2.4.2 Install Mounting Base

3-2 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A !Attention The ControlNet adapter (1734-ACNR) has a maximum dat

Page 18 - 2.4.5 Remove a Mounting Base

Chapter 3: Configuring the 1734sc-IExCH for RSLogix 5000 3-3 User’s Manual Pub. 0300257-01 Rev. A 2.) Select the module type from the Select M

Page 19 - Connections

3-4 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A 3.3.2 Add a Remote Ethernet Point IO Adapter After you have add

Page 20 - 2.5.1 Wiring Diagram

Chapter 3: Configuring the 1734sc-IExCH for RSLogix 5000 3-5 User’s Manual Pub. 0300257-01 Rev. A 2.) Select the module type from the Select Mod

Page 21

3-6 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A 2.) Select the module type from the Select Module Type pop-up

Page 22

Chapter 3: Configuring the 1734sc-IExCH for RSLogix 5000 3-7 User’s Manual Pub. 0300257-01 Rev. A Section 3.4 Use Add-On-Profile For RSLogix 5

Page 23 - Using RSLogix 5000

iii User’s Manual Pub. 0300257-01 Rev. A Table of Contents IMPORTANT NOTES ...

Page 24 - Profile

3-8 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A 3.4.2 Adding the IExCH Module To Your Logix Project Once the pr

Page 25

Chapter 3: Configuring the 1734sc-IExCH for RSLogix 5000 3-9 User’s Manual Pub. 0300257-01 Rev. A 6.) Enter an RPI Rate 7.) Configure the re

Page 26

3-10 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Generic Module Profile: [Name of remote communication module]:e

Page 27

Chapter 3: Configuring the 1734sc-IExCH for RSLogix 5000 3-11 User’s Manual Pub. 0300257-01 Rev. A Instance: 225 Size: 50 Bytes (DNET 46 Bytes)

Page 28

3-12 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A High Engineering The maximum scaled value that will be displaye

Page 29 - Add-On-Profile

Chapter 3: Configuring the 1734sc-IExCH for RSLogix 5000 3-13 User’s Manual Pub. 0300257-01 Rev. A Alarm Disable 0: Process alarms enabled for as

Page 30

3-14 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A 3.5.4 HART Pass-through Handle Timeout The Handle time out valu

Page 31 - Configuration

Chapter 3: Configuring the 1734sc-IExCH for RSLogix 5000 3-15 User’s Manual Pub. 0300257-01 Rev. A Table 3-4 (IE2CH Input Assembly) Instance: 10

Page 32

3-16 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A ANALOG STATUS BITS: CF = Channel Fault status; 0 = no error, 1

Page 33 - 3.5.1 Channel Configuration

Chapter 3: Configuring the 1734sc-IExCH for RSLogix 5000 3-17 User’s Manual Pub. 0300257-01 Rev. A Table 3-5 (IE4CH Input Assembly) Instance: 10

Page 34

iv Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A SECTION 3.7 MODULE UPDATE TIME ...

Page 35 - 3.5.3 RTS (Real Time Sample)

3-18 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A ANALOG STATUS BITS: CF = Channel Fault status; 0 = no error, 1

Page 36 - Read Input

User’s Manual Pub. 0300257-01 Rev. A Chapter 4 IExCH and HART This chapter describes how to read and write HART data using the IExCH module. This

Page 37

4-2 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A To determine if a HART device is present on a given channel the

Page 38

Chapter 4: IExCH and HART 4-3 User’s Manual Pub. 0300257-01 Rev. A 4.2.1 Auto-Scanning of Dynamic HART Variables (PV, SV, TV, FV) The module will

Page 39

4-4 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Section 4.3 Supported HART CIP Messages CIP messages can be sent

Page 40 - Update Time

Chapter 4: IExCH and HART 4-5 User’s Manual Pub. 0300257-01 Rev. A 3. Every 2 minutes if bit remains set. The following table describes the class,

Page 41 - IExCH and HART

4-6 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Table 4-4 (Request Succeeded) HART Read Extended Status - Reply pa

Page 42

Chapter 4: IExCH and HART 4-7 User’s Manual Pub. 0300257-01 Rev. A notify the user when to send the Get HART Device Information message to retrieve

Page 43

4-8 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Table 4-9 (Request Failed) HART Get Device Information - Reply pac

Page 44 - CIP Messages

Chapter 4: IExCH and HART 4-9 User’s Manual Pub. 0300257-01 Rev. A HART Get Device Information - Reply packet structure Offset Field Value Defi

Page 45 - Field Value Definition

v User’s Manual Pub. 0300257-01 Rev. A PREFACE Read this preface to familiarize yourself with the rest of the manual. This preface covers the follo

Page 46

4-10 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A pass-through command and the pass-through response data, if avail

Page 47

Chapter 4: IExCH and HART 4-11 User’s Manual Pub. 0300257-01 Rev. A Table 4-13 (Reply Data) HART Ladder Passthrough Init - Reply packet structure

Page 48

4-12 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Table 4-16 (Reply Data) HART Ladder Passthrough Query - Reply pac

Page 49

Chapter 4: IExCH and HART 4-13 User’s Manual Pub. 0300257-01 Rev. A Figure 4-3 (HART Pass-through)

Page 50

4-14 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A 4.3.4 Flush Queue The Flush Queue message can be sent to have the

Page 51

Chapter 4: IExCH and HART 4-15 User’s Manual Pub. 0300257-01 Rev. A The following tables describe the possible message responses. Table 4-20 (Requ

Page 52

4-16 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Table 4-24 (Reply Data) Resume Normal HART acquisitions - Reply

Page 53

User’s Manual Pub. 0300257-01 Rev. A Appendix A Module Specifications General Specifications Parameter 1734sc-IE4CH Specification 1734sc-IE2CH Spe

Page 54 - 4.3.4 Flush Queue

A-2 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Input update rate (per module) 488 ms @ Notch=50/60Hz (def) 248 m

Page 55

Appendix A: IExCH Specifications A-3 User’s Manual Pub. 0300257-01 Rev. A Environmental Specifications Environmental Tests Industry Standards Te

Page 56

vi Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A o Calling 1.800.963.9548 (USA/Canada) or 001.330.725.1574 (Outsi

Page 57 - Module Specifications

A-4 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Agency Certifications The following certifications will be obtain

Page 58

User’s Manual Pub. 0300257-01 Rev. A Appendix B Additional HART Protocol Information This appendix describes the HART protocol and provides referenc

Page 59 - Environmental Specifications

B-2 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A to its own command messages. The 1734sc-IE2CH or 1734sc-IE4CH modu

Page 60 - Agency Certifications

Appendix B: Additional HART Protocol Information B-3 User’s Manual Pub. 0300257-01 Rev. A Response Code Description If Bit 7 is And Bits 6…0 ar

Page 61 - Protocol Information

B-4 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Table B-3 (HART Universal Commands) Command Data in Command Data

Page 62

Appendix B: Additional HART Protocol Information B-5 User’s Manual Pub. 0300257-01 Rev. A Command Data in Command Data in Reply Contained in

Page 63

B-6 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Command Data in Command Data in Reply Contained in No. Func

Page 64

Appendix B: Additional HART Protocol Information B-7 User’s Manual Pub. 0300257-01 Rev. A Command Data in Command Data in Reply Contained in

Page 65

B-8 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Command Data in Command Data in Reply Contained in No. Func

Page 66

Appendix B: Additional HART Protocol Information B-9 User’s Manual Pub. 0300257-01 Rev. A Command Data in Command Data in Reply Contained in

Page 67

vii User’s Manual Pub. 0300257-01 Rev. A Conventions Used in This Manual The following conventions are used throughout this manual: • Bulleted l

Page 68

B-10 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Table B-5 (HART PV, SV, TV, and FV Status Values) HART PV, SV, TV

Page 69 - TV, and FV

User’s Manual Pub. 0300257-01 Rev. A Appendix C Manufacturer Identification Codes This appendix identifies the manufacturer by their assigned code.

Page 70

C-2 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Decimal Hex Company Name 41 29 Sensall 42 2A Siemens

Page 71 - Identification Codes

Appendix C: Manufacturer Identification Codes C-3 User’s Manual Pub. 0300257-01 Rev. A Decimal Hex Company Name 94 5E ACCUTECH 95 5F F

Page 72

C-4 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Decimal Hex Company Name 147 93 WELLTECH SHANGHAI 148 94

Page 73

Appendix C: Manufacturer Identification Codes C-5 User’s Manual Pub. 0300257-01 Rev. A Decimal Hex Company Name 200 C8 JSP Nova Paka 201

Page 74

C-6 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Decimal Hex Company Name 24603 601B TC Fluid Control 24604

Page 75

User’s Manual Pub. 0300257-01 Rev. A Appendix D Engineering Unit Codes This table maps engineering unit code numbers to their meaning and abbreviati

Page 76

D-2 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Unit Codes Description from HART Specification Abbreviated Units

Page 77 - Unit Codes

Appendix D: Engineering Unit Codes D-3 User’s Manual Pub. 0300257-01 Rev. A Unit Codes Description from HART Specification Abbreviated Units 94

Page 78

viii Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A

Page 79

D-4 Point IO™ 2/4 Channel Analog HART Module User’s Manual Pub. 0300257-01 Rev. A Unit Codes Description from HART Specification Abbreviated Units

Page 80

User’s Manual Pub. 0300257-01 Rev. A Index A Add-On-Profile · 3-7 B block diagram · 1-4 C Channel Configuration · 3-11 CIP Messages Supported · 4-4

Page 81

User’s Manual Pub. 0300257-01 Rev. A S Specifications · A-1 Suspend HART Communication · 4-14 U Universal Commands · B-3 W Wiring Diagram · 2-8

Page 82 - Wiring Diagram · 2-8

User’s Manual Pub. 0300257-01 Rev. A Getting Technical Assistance Note that your module contains electronic components which are susceptible to dam

Page 83 - Conformity

User’s Manual Pub. 0300257-01 Rev. A ©2011, Spectrum Controls, Inc. All rights reserved. Specifications subject to change without notice. The Encom

Page 84

User’s Manual Pub. 0300257-01 Rev. A Chapter 1 Module Overview The 1734sc-IE2CH module has two analog input channels with HART and the IE4CH has fou