Appendix A: IExCH Specifications A-3
User’s Manual Pub. 0300257-01 Rev. A
Environmental Specifications
Environmental Tests Industry Standards Test Level Limits
Temperature (Operating)
(Performance Criteria A)
IEC60068-2-1: (Test Ad, Operating Cold),
IEC60068-2-2: (Test Bd, Operating Dry Heat),
IEC60068-2-14: (Test Nb, Operating Thermal Shock)
-20 to 55°C (-4 to 131°F)
(natural convection cooling)
Temperature
(Non-operating)
(Performance Criteria B)
IEC60068-2-1:
(Test Ab, Unpackaged Non-operating Cold),
IEC60068-2-2:
(Test Bb, Unpackaged Non-operating Dry Heat),
IEC60068-2-14:
(Test Na, Unpackaged Non-operating Thermal Shock)
-40 to 85°C (-40 to 185°F)
Humidity (Operating)
(Performance Criteria A)
IEC60068-2-30:
(Test Db, Unpackaged Damp Heat):
80 - 95% Condensing
20-60-20°C Temp Cycle
Vibration (Operating)
(Performance Criteria A)
IEC60068-2-6: (Test Fc, Operating) 10 to 500Hz, 5g
Shock (Operating)
(Performance Criteria A)
IEC60068-2-27: (Test Ea, Unpackaged Shock)
30 g,11ms half-sine (3 mutually
perpendicular axes)
Shock (Non-operating)
(Performance Criteria B)
IEC60068-2-27: (Test Ea, Unpackaged Shock)
50 g, 11ms half-sine (3 mutually
perpendicular axes)
Packaged Vibration ES# PC003, Revision A
5 to 20 Hz 1 g. 1 hour each axis. 4
min sweep.
Packaged Shock
("drop test")
ES# PC004, Revision A
Drop from 48 in. 10 times each in
various orientations.
Radiated Emissions CSIPR 11; Group 1, Class A (Enclosure) Class A
Conducted Emissions IEC 61000-6-4:2007 Group 1, Class A (AC Mains)
ESD immunity
(Performance Criteria B)
IEC 61000-4-2
Rockwell Document QTP#X0327
6kV Indirect (Coupling Plate)
6kV Contact Discharge ( to points of
initial contact)
8kV Air Discharge ( to points of
initial contact)
Radiated RF immunity
(Performance Criteria A)
IEC 61000-4-3: Level 3
Rockwell Document QTP#X0327
10 V/M with 1 kHz sine-wave
80%AM from 80…2000 MHz
10 V/M with 200 Hz sine-wave 50%
Pulse 100%AM @900 MHz
10 V/M with 200 Hz sine-wave 50%
Pulse 100%AM @1890 MHz
1 V/M with 1 kHz sine-wave
80%AM from 2000…2700 MHz
EFT/B immunity
(Performance Criteria B)
IEC 61000-4-4*
Rockwell Document QTP#X0327
± 3 kV @ 5 kHz for 5 minutes on
communication ports and power
ports
± 3 kV @ 5 kHz for 5 minutes on
(PE) ground port
Surge transient immunity
(Performance Criteria A)
IEC 61000-4-5
Rockwell Document QTP#X0327
±- 2 kV line-earth {CM}@ 2 on
communications ports
± 2kV CM @ 42, ±1kV DM @
42 on unshielded ports
Conducted RF immunity
(Performance Criteria A)
IEC 61000-4-6
Rockwell Document QTP#X0327
10V rms with 1 kHx sine wave
80%AM from 150 kHz…80
MHz on communications, power
ports and (PE) ground
Magnetic Field Not Applicable
AC Mains Voltage Dips,
Interruptions and
Variations
Not Applicable
DC Mains Voltage Dips,
Interruptions and
Variations
Not Applicable
Oscillatory Waves Not Applicable
C-Tick (Australia) AS/NZS CISPR 11 (Group 1, Class A) Class A